Creatine Kinase CAS 9001-15-4

Creatine Kinase CAS 9001-15-4

Identification

CAS Number

9001-15-4

Name

Creatine Kinase

Synonyms

2,2′-[(2,5-Dichlor-3,6-dioxo-1,4-cyclohexadien-1,4-diyl)diimino]dibenzoesäure [German] [ACD/IUPAC Name]
2,2′-[(2,5-Dichloro-3,6-dioxo-1,4-cyclohexadiene-1,4-diyl)diimino]dibenzoic acid [ACD/IUPAC Name]
Acide 2,2′-[(2,5-dichloro-3,6-dioxo-1,4-cyclohexadiène-1,4-diyl)diimino]dibenzoïque [French] [ACD/IUPAC Name]
Benzoic acid, 2,2′-[(2,5-dichloro-3,6-dioxo-1,4-cyclohexadiene-1,4-diyl)diimino]bis- [ACD/Index Name]
2-[[4-(2-carboxyanilino)-2,5-dichloro-3,6-dioxocyclohexa-1,4-dien-1-yl]amino]benzoic acid
9001-15-4 [RN]

SMILES

c1ccc(c(c1)C(=O)O)NC2=C(C(=O)C(=C(C2=O)Cl)Nc3ccccc3C(=O)O)Cl

StdInChI

InChI=1S/C20H12Cl2N2O6/c21-13-15(23-11-7-3-1-5-9(11)19(27)28)17(25)14(22)16(18(13)26)24-12-8-4-2-6-10(12)20(29)30/h1-8,23-24H,(H,27,28)(H,29,30)

StdInChIKey

MYMYWPXTGWBPLRUHFFFAOYSA-N

Molecular Formula

C20H12Cl2N2O6

Molecular Weight

447.225 

EINECS

232-585-5

MDL Number

MFCD00130876

Safety Data

Personal Protective Equipment

EyeshieldsGlovestype N95 (US)type P1 (EN143) respirator filter

RIDADR 

NONH for all modes of transport

WGK Germany

3

Specifications and Other Information of Our
Creatine Kinase CAS 9001-15-4

General Assay Characteristics

Method
Enzymatic/RATE A/E
ReagentsReady to use
CalibratorsLevel 1-0.0 U/L; Level 2-200 U/L
Calibration Stability28 days
Sample TypeEDTA,SST,Serum,Heparinised plasma
Assay Range25-1000U/L undiluted
Standardisation

Assay Principle

Proposed Hcy Recipe

Reagent I

CompositionConcentrationCatalog Number
Imidazolel buffer130mM
Mg2+12.8mM
AMP6.6mMCS007
AP5A-3li13uMCS011
D-G40mM
β-NADP2.6mMCS004
ADP2.6mMCS005
NAC25mM
Detergent, Preservative

Reagent II

CompositionConcentrationCatalog Number
Tris-HCl buffer50mM
CP156mMCS010
G6PDH36KU/LEM008
HK>36KU/LEM007
Detergent, Preservative

Major reagent ingredients made by Assay Specilist Lab are list on right

Standard&Control

Home Made: CKBB, white amorphous powder, lyophilized ; Commercial available: RANDOX: 218U/L, Cat# HE1530

Reaction curve chart

Calibrator 1
Calibrator 1

Known Application

Commonly used in biochemical research, food preservation, clinically used as a diagnostic enzyme, determination of phosphoric acid and creatine phosphate.

This product is developed by our R&D company Ulcho Biochemical Ltd(http://www.ulcho.com/), and here is the corresponding linkhttp://www.ulcho.com/creatine-kinase-cas-9001-15-4/

Quick Inquiry

Fill out our inquiry form and one of our experts will be in touch with you shortly (Please change screen to horizontal for complete browsing if you are checking Watson on your mobile phone).
* indicates required field